webmaster@we-con.vn
0342944645
Wecon 4 channel thermocouple module, supports RS485 Modbus communication.
Item
Centigrade
Fahrenheit
Both °C and °F readings are available by reading the appropriate buffer memory area.
Analog input signal
Thermocouple: Type K or J (either can be used for each channel), 4 channels.
Rated temperature range
Type K
-100°C to 1200°C
-148°F to +2192°F
Type J
-100°C to 600°C
-148°F to +1112°F
Digital output
-1000 to 12000
-1480 to 21920
-1000 to 6000
-1480 to 11120
12-bit conversion ,save as complement of 2 in 16 bits
Resolution
0.4°C
0.72°F
0.3°C
0.54°F
Overall accuracy
±5% full scale + 1°C
Freezing point of pure water 0°C / 32°F
Conversion speed
(240ms ± 2%) × 4 channels (unused channels are not converted)
Note: Grounded thermocouples are not suitable for this module.
Wecon LX3V-2WT Weighing PLC Module
2 channels weighing signal input;
Hardware 24-bits AD input (2: 24-bit Resolution);
Support 1~2400 Hz frequency conversion;
Adjustable setting of Digital filter;
Adjustable setting of Tare weight and Net weight ;
Zero-tracking can reduce the influence of temperature drift effective.
Wecon LX3V-1WT-L Weighing PLC Module
Wecon 16 channel Input Module, supports RS485 Modbus communication.
Wecon LX3V-8EX Input PLC Module
Wecon LX3V-16EYR Relay Output PLC Module
Wecon LX3V-16EYT Transistor Output PLC Module
Wecon LX3V-16EX Input PLC Module
Wecon LX3V-8EYR Relay Output PLC Module
Wecon LX3V-8EYT Transistor Output PLC Module
Wecon LX3V-1WT Weighing PLC Module
Wecon LX3V-4AD PLC Module for Analog to Digital
Wecon LX3V-4DA PLC Module for Digital to Analog
Wecon LX3V-4PT V2 4 Thermocouple Resistance Input PLC Module
Wecon LX3V-4TC Analog Input PLC Module
Wecon LX3V-4LTC Isolation Temperature PLC Module
LX3V-4LTC is temperature control module, it has four temperature input ports and four transistor output ports (open collector). It reads data from the thermocouple, and give output value with PID control algorithm.
Wecon LX3V-8iTC Thermocouple Input PLC Module
8 channels for temperature acquiring; Multiple sensor types are supported; Supports thermocouple types like K, S, E, N, B, T, J and R.
All 8 channels are isolated from each other
Built-in cold junction compensation, external cold junction compensation, freezing cold junction compensation method.
Wecon LX3V-2WT-L Weighing PLC Module
Hardware 16-bits AD input (2: 16-bit Resolution);
Wecon LX3V-4PGA PLC Module
Supports 4-channel high speed pulse outputs
Supports Home position return, JOG, interrupt position and two-speed pulse control
Supports S-type acceleration and deceleration
Maximum support for 200k pulse output
Interrupt signal, origin signal input
2 channel weighing expansion module, 24-bit resolution, supports RS485 Modbus communication.
Wecon 16 Channel Relay Output Module, supports RS485 Modbus communication.